A battery is easier to size when the question is specific: which appliances should keep running, and for how long? A list of selected circuits is more useful than a promise of whole-home backup. Use the local examples below as a starting worksheet, then replace every assumption with appliance or installer data.
kWh and kW answer different questions
Energy in kWh describes the amount stored. Power in kW describes how quickly energy is delivered. A larger battery does not automatically provide a higher AC output. Battery-side DC ratings, inverter AC output, starting demand and the backup-circuit arrangement must all support the intended loads.
A local load worksheet
Lights, fan and household connection
- Selected LED lighting — 50 W
- One fan — 80 W
- Router — 20 W
- Laptop — 100 W
Refrigeration and evening essentials
- Selected lighting — 80 W
- Two fans — 160 W combined
- Router — 20 W
- Refrigeration, assumed cycling average — 140 W
- Television — 100 W
Broader selected household circuits
- Selected lighting — 100 W
- Fans — 240 W combined
- Router — 20 W
- Refrigeration, assumed cycling average — 200 W
- Home-office equipment — 140 W
- Freezer, assumed cycling average — 200 W
An indicative runtime, with assumptions visible
For comparison only: runtime in hours = nominal battery energy × assumed usable fraction × assumed conversion efficiency ÷ average load in kW. The example uses 90% usable energy and 90% conversion efficiency as planning assumptions, not product guarantees. Actual runtime also depends on reserve settings, temperature, ageing, standby consumption, duty cycles and the selected inverter.
Illustrative TR6000WX-Pro example
| Assumed load (W) | Indicative runtime (h) |
|---|---|
| 250 | 33.2 |
| 500 | 16.6 |
| 900 | 9.2 |
10.24 kWh nominal energy; assumptions 0.90 × 0.90. This is a calculation, not a tested local household result.
Choose the architecture before the capacity
EU 230 V and TA6000 are integrated battery-and-inverter families. A second standalone inverter is not part of their basic product architecture. TR Pro, TR standard, HP Ultra, HP K and TB are batteries that need a compatible external inverter. Match voltage range, current limits, communication protocol and firmware; nominal voltage alone does not establish compatibility.
Use the backup explorer for a first comparison, then send the selected loads, required duration and existing inverter details with your enquiry. Electrical design and final compatibility need to be confirmed for the actual project.
Questions for your installer
Can these batteries deliver full output in any hot equipment room?
Do not infer that from an operating-temperature range. Use the selected model’s charging/discharging limits, cooling and service clearances, and any available derating information. Assess the hottest expected temperature inside the room, not only outdoor weather.
Does a negative discharge limit allow below-zero charging?
No. Charging and discharging limits are different. Several supplied families list charging from 0 °C, while a negative value applies to discharge. Optional self-heating is configuration-specific and requires confirmation; HP Ultra’s temperature limits also need confirmation for the exact version.
Do these planning examples assume a current outage schedule?
No. Choose the backup hours you want to plan for and supply your actual appliance loads. Final runtime depends on usable battery energy, inverter consumption, changing loads, temperature and operating settings; this page does not state current outage frequency or schedules.