TB rack

Low-voltage battery

TB rack.

Four specified LFP battery capacities for rack-mounted storage and a compatible external inverter.

INVERTER
Compatible external inverter required
ENCLOSURE
IP20
NOMINAL ENERGY
5.12–16.076 kWh
BATTERY VOLTAGE
51.2 V nominal DC
Start your project ↗

Specifications

Model / configurationEnergy (kWh)Rated DC (kW)
TB4000X5.125
TB6000X10.2410
TB8000X14.33610
TB8500X16.07610

Wi-Fi / Bluetooth is listed for TB6000X, TB8000X and TB8500X, excluding TB4000X. Power ratings are battery-side DC.

ModelDimensions (mm)Approx. kg
TB4000X482 × 178 × 420 / W × H × D42
TB6000X482 × 223 × 550 / W × H × D78
TB8000X482 × 223 × 710 / W × H × D109.5
TB8500X482 × 223 × 710 / W × H × D112

Communication: RS485 / CAN / RS232
Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C

From a city utility room to a cooler service space, plan for your home.

Pakistan’s plains, coast and northern uplands have different climate conditions. Keep selected household essentials in the plan, then match the battery format and protected equipment space to the room’s actual heat, moisture exposure and winter temperature.

Temperature:
Charge 0 to 55 °C; discharge −20 to 60 °C
ENCLOSURE
IP20
01

Urban lowland home: fans, refrigeration and connectivity

A dry utility room gives a household energy reserve a dedicated place near the selected circuits it supports. In warmer lowland locations, the room’s airflow and heat belong alongside the appliance list in the plan.

EU combines battery and inverter for a new indoor IP21 installation. Where a suitable inverter already exists, TR Pro offers compact 51.2 V storage; select energy capacity around the desired hours and preserve cooling and service access.

Which lights, fans, refrigeration and network devices should be supported?
  • What is the highest expected temperature inside the equipment room?
02

Coastal home: protected storage and accessible connections

A sheltered service room can organise storage for a coastal household’s selected essential circuits. Describe actual coastal air, water and condensation exposure so the equipment location becomes part of the design.

Compare a compact TR Pro battery with modular HP Ultra storage, both listed with IP66 enclosures. Choose the electrical architecture for the compatible inverter and the housing for the proposed protected position.

Can coastal air, rain, wash water or condensation reach the proposed location?
  • Is the existing inverter a 51.2 V or high-voltage battery system?
03

Cooler equipment space: a reserve with a seasonal plan

Northern uplands are cooler than the lowlands, and an unheated equipment room needs its own minimum-temperature assessment. A dedicated dry space keeps the installation accessible while the charging plan follows the actual room.

Choose integrated storage for a new complete system or battery-only storage for a compatible inverter. Several supplied families list charging from 0 °C; discuss any explicitly supported TR heating option for the exact configuration when a colder room is involved.

What are the lowest and highest expected room temperatures?
  • What charging protection and confirmed heating options apply to the selected model?
Specifications
  • Use kWh to plan energy for the desired duration and kW to check which selected circuits can run together. Confirm inverter AC output, battery current limits and motor/compressor starting requirements for the final system.
  • TR Pro lists charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. HP Ultra’s temperature range needs selected-configuration confirmation. A temperature range is not a full-output derating curve.
  • Choose the exact housing with the installation space. TR Pro/HP Ultra list IP66, EU IP21 and TB rack IP20; TR standard and HP K list IP20 with IP54 optional. Shelter, water exposure, condensation and coastal corrosion still need project-specific assessment.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

The native front feature illustration and exploded callout illustration have visible layout differences and are not proven to be the same hardware revision. Keep each original view's source identity. The source has no external rear-view photograph. Internal/thermal diagrams must not be described as exterior rear or underside photos.

Original front terminal and control strip
Original front terminal and control stripFront terminal and control strip, with the negative terminal left and positive terminal right.
Negative power terminal, front left
Negative power terminal, front leftNegative terminal and minus mark at the front left.
Positive power terminal, front right
Positive power terminal, front rightPositive terminal and plus mark at the front right.
Original communication and control area
Original communication and control areaCommunication connectors, indicators and power switch on the front control strip.
Original cell and BMS construction detail
Original cell and BMS construction detailPartial internal illustration showing battery cells and the BMS board.

Know your interfaces.

Power connections

Positive power terminal
Power port on the viewer's right in the illustrated front panel, with the original plus mark.
Negative power terminal
Power port on the viewer's left in the illustrated front panel, with the original minus mark.

Communication

Dry Connect (source label)
Source names this a communication port labelled 'Dry Connect'. Contact logic, pinout and electrical ratings are not given.
COM0 / COM1 parallel ports
Ports explicitly captioned 'Parallel Port' in this source. Parallel-system limits and wiring are not supplied.
CAN / RS485
Communication port group named CAN/RS485. Appearance alone does not prove Ethernet networking or a compatible inverter protocol.
RS232
Communication port named RS232; exact pinout and adapter requirements are not provided.

Controls & indicators

Power switch
Power on/off switch as described in the original caption. Operating sequence is not supplied.
SOC / ALM / RUN indicators
Indicator-light group identified by the source. Individual colour meanings and diagnostic codes are not specified.
Address identification control
Control labelled 'Add'; the caption states automatic address identification. Setup method and address logic are not specified.

Structure & mounting

Laser welding
The brochure describes laser welding for the aluminium-plate and cell connection. It is an internal construction feature, not a port.
Steel holder
Internal steel holder identified as fixing the cells; not an external connector.
Plastic steel belt (source wording)
Cell-retaining band described in the source as preventing movement-related impacts; material performance is not independently validated.
Built-in smart BMS
Built-in BMS. The manufacturer lists temperature protection, short-circuit protection and balancing; this extraction does not independently verify those functions.
Portable handle
Steel handle as described in the source. It is not an electrical port.

Source: Residential ESS brochure · PDF page 7 · printed pages 13-14