HP Ultra

High-voltage battery

HP Ultra.

A modular aluminium-alloy LFP battery stack. Six specified configurations from 8 to 48 kWh, for integration with a compatible external inverter.

INVERTER
Compatible external inverter required
ENCLOSURE
IP66 / aluminium alloy
NOMINAL ENERGY
8–48 kWh
BATTERY VOLTAGE
Confirm selected configuration
Start your project ↗

Specifications

Model / configurationEnergy (kWh)Max. DC (kW)
HP Ultra-8.084
HP Ultra-16.0168
HP Ultra-24.02412
HP Ultra-32.03216
HP Ultra-40.04020
HP Ultra-48.04824

System voltage and inverter compatibility must be confirmed for the chosen capacity. Floor-standing or wall-mounted installation is listed. Module additions require system review.

ModelDimensions (mm)Approx. kg
HP Ultra-8.0950 × 315 × 575 / W × D × H75
HP Ultra-16.0950 × 315 × 880 / W × D × H130
HP Ultra-24.0950 × 315 × 1185 / W × D × H185
HP Ultra-32.0950 × 315 × 1490 / W × D × H240
HP Ultra-40.0950 × 315 × 1795 / W × D × H295
HP Ultra-48.0950 × 315 × 2100 / W × D × H350

Communication: CAN / RS485 / Wi-Fi / Bluetooth
Temperature: Confirm selected configuration

From a city utility room to a cooler service space, plan for your home.

Pakistan’s plains, coast and northern uplands have different climate conditions. Keep selected household essentials in the plan, then match the battery format and protected equipment space to the room’s actual heat, moisture exposure and winter temperature.

Temperature:
Confirm selected configuration
ENCLOSURE
IP66 / aluminium alloy
01

Urban lowland home: fans, refrigeration and connectivity

A dry utility room gives a household energy reserve a dedicated place near the selected circuits it supports. In warmer lowland locations, the room’s airflow and heat belong alongside the appliance list in the plan.

EU combines battery and inverter for a new indoor IP21 installation. Where a suitable inverter already exists, TR Pro offers compact 51.2 V storage; select energy capacity around the desired hours and preserve cooling and service access.

Which lights, fans, refrigeration and network devices should be supported?
  • What is the highest expected temperature inside the equipment room?
02

Coastal home: protected storage and accessible connections

A sheltered service room can organise storage for a coastal household’s selected essential circuits. Describe actual coastal air, water and condensation exposure so the equipment location becomes part of the design.

Compare a compact TR Pro battery with modular HP Ultra storage, both listed with IP66 enclosures. Choose the electrical architecture for the compatible inverter and the housing for the proposed protected position.

Can coastal air, rain, wash water or condensation reach the proposed location?
  • Is the existing inverter a 51.2 V or high-voltage battery system?
03

Cooler equipment space: a reserve with a seasonal plan

Northern uplands are cooler than the lowlands, and an unheated equipment room needs its own minimum-temperature assessment. A dedicated dry space keeps the installation accessible while the charging plan follows the actual room.

Choose integrated storage for a new complete system or battery-only storage for a compatible inverter. Several supplied families list charging from 0 °C; discuss any explicitly supported TR heating option for the exact configuration when a colder room is involved.

What are the lowest and highest expected room temperatures?
  • What charging protection and confirmed heating options apply to the selected model?
Specifications
  • Use kWh to plan energy for the desired duration and kW to check which selected circuits can run together. Confirm inverter AC output, battery current limits and motor/compressor starting requirements for the final system.
  • TR Pro lists charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. HP Ultra’s temperature range needs selected-configuration confirmation. A temperature range is not a full-output derating curve.
  • Choose the exact housing with the installation space. TR Pro/HP Ultra list IP66, EU IP21 and TB rack IP20; TR standard and HP K list IP20 with IP54 optional. Shelter, water exposure, condensation and coastal corrosion still need project-specific assessment.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

Six specified 8-48kWh configurations only. Original introduction figures show an unlabeled representative stack; no underside, complete installed rear, wiring pinout or activation interface is supplied. DC poles/breaker/heatsinks and communication/parallel/GND belong to different illustrated faces. Small native drawings must not be presented as high-resolution product photography. The broader '8.0-128.0' heading is not a list of additional individually specified models.

DC electrical / heatsink face - original callouts
DC electrical / heatsink face - original calloutsDC-side view showing the switch, battery terminals, DC breaker and heat-dissipation plate.
Communication and parallel-interface face - original callouts
Communication and parallel-interface face - original calloutsCommunication-side labels for inverter links, backup communication, BMS debugging, parallel COM1/COM2 and GND.
Communication-side detail (partial oblique view)
Communication-side detail (partial oblique view)Oblique detail of the stack's communication-side connector area.
Module top / mating surfaces
Module top / mating surfacesBattery module top and mating surfaces.

Know your interfaces.

Power connections

Positive Pole
Positive terminal identified by the original leader line on the electrical face.
Negative Pole
Negative terminal identified by the original leader line on the electrical face.

Communication

Bluetooth/WIFI Antenna
Antenna label on the upper communication-side area.
Backup Com
The brochure labels this connection 'Backup Com' but does not explain its exact role.
INV CAN/RS485 Com
The INV-labelled CAN/RS485 communication connection shown in the original diagram.
Parallel COM1
First parallel-communication label near the lower part of the illustrated interface face.
Parallel COM2
Second parallel-communication label near the lower part of the illustrated interface face.

Controls & indicators

Switch
Switch labelled on the DC electrical-side illustration; its detailed switching function is not specified.
DC Breaker
DC breaker on the electrical / heatsink face.
Breathing Light
Light strip called out at the upper front portion in the oblique construction view.

Structure & mounting

Heat Dissipation Aluminum Plate
Heat-dissipation aluminum plate called out on the slim electrical-side illustration.
Wall Mounted Bracket
Mounting brackets shown on the vent-side illustration.
PDU
PDU labels the top unit in the component hierarchy; the brochure does not expand the abbreviation.
Module
Repeated battery sections below the top PDU.
Base
Base at the bottom of the illustrated stack.
BMS Debugging Interface
BMS debugging interface identified on the communication-side illustration.
Pressure Relief Valve
Pressure-relief component called out in the communication-side oblique view.
GND
Ground connection labelled GND at the bottom of the interface-side illustration.

Source: Residential ESS brochure · PDF page 5 · printed pages 9-10