HP K

High-voltage battery

HP K.

Four to eight LFP battery modules in five specified stacked configurations. Match the selected voltage and communication settings to a compatible external inverter.

INVERTER
Compatible external inverter required
ENCLOSURE
IP20; IP54 optional
NOMINAL ENERGY
20.48–40.96 kWh
BATTERY VOLTAGE
204.8–409.6 V nominal DC
Start your project ↗

Specifications

Model / configurationEnergy (kWh)Rated DC (kW)
HP2000K20.4820
HP2500K25.625
HP3000K30.7230
HP3500K35.8435
HP4000K40.9640

Battery-side DC ratings are not inverter AC output ratings. Confirm the inverter DC voltage window for the chosen module count.

ModelDimensions (mm)Approx. kg
HP2000K580 × 390 × 918 / L × W × H213
HP2500K580 × 390 × 1089 / L × W × H259.5
HP3000K580 × 390 × 1260 / L × W × H306
HP3500K580 × 390 × 1431 / L × W × H352.5
HP4000K580 × 390 × 1602 / L × W × H399

Communication: RS485 / CAN; Wi-Fi / Bluetooth optional
Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C

From a city utility room to a cooler service space, plan for your home.

Pakistan’s plains, coast and northern uplands have different climate conditions. Keep selected household essentials in the plan, then match the battery format and protected equipment space to the room’s actual heat, moisture exposure and winter temperature.

Temperature:
Charge 0 to 55 °C; discharge −20 to 60 °C
ENCLOSURE
IP20; IP54 optional
01

Urban lowland home: fans, refrigeration and connectivity

A dry utility room gives a household energy reserve a dedicated place near the selected circuits it supports. In warmer lowland locations, the room’s airflow and heat belong alongside the appliance list in the plan.

EU combines battery and inverter for a new indoor IP21 installation. Where a suitable inverter already exists, TR Pro offers compact 51.2 V storage; select energy capacity around the desired hours and preserve cooling and service access.

Which lights, fans, refrigeration and network devices should be supported?
  • What is the highest expected temperature inside the equipment room?
02

Coastal home: protected storage and accessible connections

A sheltered service room can organise storage for a coastal household’s selected essential circuits. Describe actual coastal air, water and condensation exposure so the equipment location becomes part of the design.

Compare a compact TR Pro battery with modular HP Ultra storage, both listed with IP66 enclosures. Choose the electrical architecture for the compatible inverter and the housing for the proposed protected position.

Can coastal air, rain, wash water or condensation reach the proposed location?
  • Is the existing inverter a 51.2 V or high-voltage battery system?
03

Cooler equipment space: a reserve with a seasonal plan

Northern uplands are cooler than the lowlands, and an unheated equipment room needs its own minimum-temperature assessment. A dedicated dry space keeps the installation accessible while the charging plan follows the actual room.

Choose integrated storage for a new complete system or battery-only storage for a compatible inverter. Several supplied families list charging from 0 °C; discuss any explicitly supported TR heating option for the exact configuration when a colder room is involved.

What are the lowest and highest expected room temperatures?
  • What charging protection and confirmed heating options apply to the selected model?
Specifications
  • Use kWh to plan energy for the desired duration and kW to check which selected circuits can run together. Confirm inverter AC output, battery current limits and motor/compressor starting requirements for the final system.
  • TR Pro lists charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. HP Ultra’s temperature range needs selected-configuration confirmation. A temperature range is not a full-output derating curve.
  • Choose the exact housing with the installation space. TR Pro/HP Ultra list IP66, EU IP21 and TB rack IP20; TR standard and HP K list IP20 with IP54 optional. Shelter, water exposure, condensation and coastal corrosion still need project-specific assessment.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

The original front/color-screen diagram shows four 5.12kWh sections; the family specification table spans four to eight modules. The connection/control face is not explicitly named rear. No separate GND, parallel COM1/COM2, INV CAN/RS485 or BMS debugging label is printed for this family, so none is imported from HP Ultra. The brochure supplies no pinout or installation/activation sequence.

Connection/control face - original labels
Connection/control face - original labelsCOM1 reserve, COM2 inverter connection, DC24V/AC230V activation and control switches.
Color-screen face
Color-screen faceFront view of the color-screen unit and stacked battery modules.
PDU connector and control detail
PDU connector and control detailTop-unit panel with connectors, indicators and switches.
Color-screen top-unit detail
Color-screen top-unit detailColor-screen area on the front of the top unit.
Separated module stack detail
Separated module stack detailSeparated battery modules showing their mating surfaces.

Know your interfaces.

Power connections

Negative Pole
Negative terminal as identified by the original leader line.
Positive Pole
Positive terminal as identified by the original leader line.
Battery Activation (DC24V)
A separately labelled DC24V battery-activation point in the original connection-face diagram.
Battery Activation (AC230V)
A separately labelled AC230V battery-activation point in the original connection-face diagram.

Communication

COM1: Reserve
COM1 is explicitly labelled Reserve.
COM2: Connect To Inverter
The source explicitly assigns the inverter connection to COM2.

Controls & indicators

Color Screen
Screen identified on the opposite, closed front-top face.
Air Switch
Switch/breaker labelled Air Switch on the connection/control face.
AC Switch
A separate control labelled AC Switch.
Alarm Lights
Alarm indicator group identified by the original leader line.
Running Lights
Running indicator group identified by the original leader line.
Adjustable Status Indicator
Feature caption on the separate status-line corner illustration on printed page 11.

Structure & mounting

PDU
The top unit identified as PDU above the battery sections; the source does not expand the abbreviation.
5.12kWh
Four repeated 5.12kWh sections are called out in the introduction diagram.
Chassis
Bottom chassis called out below the battery stack.

Source: Residential ESS brochure · PDF page 6 · printed pages 11-12