# TR standard.

![TR standard](https://pk.elvorka.com/assets/optimized/54d556eb3b41e40a-1295-q92.webp)

Low-voltage battery

# TR standard.

Five specified capacities in a wall-mounted LFP battery format. Select the capacity, enclosure and a compatible external inverter for the installation.

INVERTER  Compatible external inverter required

ENCLOSURE  IP20; IP54 optional

NOMINAL ENERGY  5.12–20.07 kWh

BATTERY VOLTAGE  51.2 V nominal DC

[Start your project ↗](https://pk.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | Nominal DC (V) |
| --- | --- | --- |
| TR4000WX | 5.12 | 51.2 |
| TR6000WX | 10.24 | 51.2 |
| TR8000WX | 14.336 | 51.2 |
| TR8500WX | 16.076 | 51.2 |
| TR10000WX | 20.07 | 51.2 |

Self-heating is optional. Confirm the charge/discharge current, output power and enclosure option for the exact model and inverter.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| TR4000WX | 400 × 750 × 160 / W × H × D | 53.5 |
| TR6000WX | 600 × 750 × 160 / W × H × D | 95 |
| TR8000WX | 480 × 822 × 245 / W × H × D | 110 |
| TR8500WX | 480 × 822 × 245 / W × H × D | 115 |
| TR10000WX | 500 × 922 × 265 / W × H × D | 145 |

Communication: RS485 / RS232 / CAN; Wi-Fi / Bluetooth
Temperature: Charge 0 to 55 °C

## From a city utility room to a cooler service space, plan for your home.

Pakistan’s plains, coast and northern uplands have different climate conditions. Keep selected household essentials in the plan, then match the battery format and protected equipment space to the room’s actual heat, moisture exposure and winter temperature.

Temperature:  Charge 0 to 55 °C

ENCLOSURE  IP20; IP54 optional

01

### Urban lowland home: fans, refrigeration and connectivity

A dry utility room gives a household energy reserve a dedicated place near the selected circuits it supports. In warmer lowland locations, the room’s airflow and heat belong alongside the appliance list in the plan.

EU combines battery and inverter for a new indoor IP21 installation. Where a suitable inverter already exists, TR Pro offers compact 51.2 V storage; select energy capacity around the desired hours and preserve cooling and service access.

Which lights, fans, refrigeration and network devices should be supported?

- What is the highest expected temperature inside the equipment room?

02

### Coastal home: protected storage and accessible connections

A sheltered service room can organise storage for a coastal household’s selected essential circuits. Describe actual coastal air, water and condensation exposure so the equipment location becomes part of the design.

Compare a compact TR Pro battery with modular HP Ultra storage, both listed with IP66 enclosures. Choose the electrical architecture for the compatible inverter and the housing for the proposed protected position.

Can coastal air, rain, wash water or condensation reach the proposed location?

- Is the existing inverter a 51.2 V or high-voltage battery system?

03

### Cooler equipment space: a reserve with a seasonal plan

Northern uplands are cooler than the lowlands, and an unheated equipment room needs its own minimum-temperature assessment. A dedicated dry space keeps the installation accessible while the charging plan follows the actual room.

Choose integrated storage for a new complete system or battery-only storage for a compatible inverter. Several supplied families list charging from 0 °C; discuss any explicitly supported TR heating option for the exact configuration when a colder room is involved.

What are the lowest and highest expected room temperatures?

- What charging protection and confirmed heating options apply to the selected model?

Specifications

- Use kWh to plan energy for the desired duration and kW to check which selected circuits can run together. Confirm inverter AC output, battery current limits and motor/compressor starting requirements for the final system.

- TR Pro lists charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. HP Ultra’s temperature range needs selected-configuration confirmation. A temperature range is not a full-output derating curve.

- Choose the exact housing with the installation space. TR Pro/HP Ultra list IP66, EU IP21 and TB rack IP20; TR standard and HP K list IP20 with IP54 optional. Shelter, water exposure, condensation and coastal corrosion still need project-specific assessment.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

Five model names provide family context, but the compact callout housing is not individually assigned to a SKU. The roller annotation expressly names TR8000WX and TR8500WX. Native photo detail is limited; no replacement surface or port detail is synthesized.

[![Front controls and side terminals](https://pk.elvorka.com/assets/product-details/tr-standard-controls-annotated.png)](https://pk.elvorka.com/assets/product-details/tr-standard-controls-annotated.png)

Front controls and side terminals  Touch screen, status indicators, communication ports and DC terminals on the illustrated cabinet.

[![Rear bracket and terminal-side labels](https://pk.elvorka.com/assets/product-details/tr-standard-rear-bracket-annotated.png)](https://pk.elvorka.com/assets/product-details/tr-standard-rear-bracket-annotated.png)

Rear bracket and terminal-side labels  Rear mounting bracket and side terminal area of the illustrated battery.

[![Circuit control switch detail](https://pk.elvorka.com/assets/product-details/tr-standard-switch-closeup.png)](https://pk.elvorka.com/assets/product-details/tr-standard-switch-closeup.png)

Circuit control switch detail  Circuit control switch with ON/OFF markings.

[![Original rear three-quarter view](https://pk.elvorka.com/assets/product-details/tr-standard-rear-threequarter.png)](https://pk.elvorka.com/assets/product-details/tr-standard-rear-threequarter.png)

Original rear three-quarter view  Rear three-quarter view showing the mounting bracket and terminal side.

[![Original side profile](https://pk.elvorka.com/assets/product-details/tr-standard-side-profile.png)](https://pk.elvorka.com/assets/product-details/tr-standard-side-profile.png)

Original side profile  Side profile showing communication ports and the recessed handle.

### Know your interfaces.

#### Power connections

Negative battery terminal  Negative DC battery power terminal as identified by the original arrow.

Positive battery terminal  Positive DC battery power terminal as identified by the original arrow.

#### Communication

Wi-Fi / Bluetooth  Wi-Fi/Bluetooth feature identified in the callout; no app or pairing workflow is established here.

Dry contact  Dry-contact interface identified; contact logic, pinout and electrical ratings are not supplied.

RS232 / CAN / RS485  Communications interfaces named in the source; protocol compatibility and wiring require separate confirmation.

COM0 / COM1  Ports named COM0/COM1. This page does not state their role, pinout or parallel-system limits.

#### Controls & indicators

Touch screen  Touch-screen display identified in the original callout.

Running status indicator  Running-status indication; source spelling is 'Runing Status'. Indicator logic is not specified.

Alarm indicator  Alarm indication identified in the source.

SOC indicator  SOC indicator identified in the source; display thresholds are not specified.

Reset control  Reset control identified by the source; operating procedure is not given on this page.

Battery switch  Battery switch identified in the source; no switching rating is given in this callout.

#### Structure & mounting

Folding handle  Mechanical folding handle; not an electrical connector.

Wall-mounted bracket  Wall-mounting bracket identified in the source; mounting load and fixing details are not supplied here.

Rollers  Rollers; the original annotation explicitly names TR8000WX and TR8500WX. Not an electrical interface.

Source: Residential ESS brochure · PDF page 3 · printed pages 5-6

---

https://pk.elvorka.com/en/products/tr-standard/

ELVORKA · eric@elvorka.com