# TR Pro.

![TR Pro](https://pk.elvorka.com/assets/optimized/46a9d9acb1b4d427-1560-q92.webp)

Low-voltage battery

# TR Pro.

LFP battery storage in a wall-mounted format, with three specified models and an IP66 enclosure. Pair with a compatible external inverter.

INVERTER  Compatible external inverter required

ENCLOSURE  IP66

NOMINAL ENERGY  10.24 / 16.076 kWh

BATTERY VOLTAGE  51.2 V nominal DC

[Start your project ↗](https://pk.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | Rated DC (kW) |
| --- | --- | --- |
| TR6000WX-Pro | 10.24 | 10 |
| TR8500WX-Pro | 16.076 | 10 |
| TR8500WX-ProU | 16.076 | 10 |

Self-heating is optional. Power ratings are battery-side DC; actual AC output depends on the selected inverter.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| TR6000WX-Pro | 802 × 620 × 179 / H × L × D | 95 |
| TR8500WX-Pro | 822 × 500 × 250 / H × L × D | 115.5 |
| TR8500WX-ProU | 872 × 500 × 250 / H × L × D | 120 |

Communication: RS485 / RS232 / CAN; Wi-Fi / Bluetooth
Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C

## From a city utility room to a cooler service space, plan for your home.

Pakistan’s plains, coast and northern uplands have different climate conditions. Keep selected household essentials in the plan, then match the battery format and protected equipment space to the room’s actual heat, moisture exposure and winter temperature.

Temperature:  Charge 0 to 55 °C; discharge −20 to 60 °C

ENCLOSURE  IP66

01

### Urban lowland home: fans, refrigeration and connectivity

A dry utility room gives a household energy reserve a dedicated place near the selected circuits it supports. In warmer lowland locations, the room’s airflow and heat belong alongside the appliance list in the plan.

EU combines battery and inverter for a new indoor IP21 installation. Where a suitable inverter already exists, TR Pro offers compact 51.2 V storage; select energy capacity around the desired hours and preserve cooling and service access.

Which lights, fans, refrigeration and network devices should be supported?

- What is the highest expected temperature inside the equipment room?

02

### Coastal home: protected storage and accessible connections

A sheltered service room can organise storage for a coastal household’s selected essential circuits. Describe actual coastal air, water and condensation exposure so the equipment location becomes part of the design.

Compare a compact TR Pro battery with modular HP Ultra storage, both listed with IP66 enclosures. Choose the electrical architecture for the compatible inverter and the housing for the proposed protected position.

Can coastal air, rain, wash water or condensation reach the proposed location?

- Is the existing inverter a 51.2 V or high-voltage battery system?

03

### Cooler equipment space: a reserve with a seasonal plan

Northern uplands are cooler than the lowlands, and an unheated equipment room needs its own minimum-temperature assessment. A dedicated dry space keeps the installation accessible while the charging plan follows the actual room.

Choose integrated storage for a new complete system or battery-only storage for a compatible inverter. Several supplied families list charging from 0 °C; discuss any explicitly supported TR heating option for the exact configuration when a colder room is involved.

What are the lowest and highest expected room temperatures?

- What charging protection and confirmed heating options apply to the selected model?

Specifications

- Use kWh to plan energy for the desired duration and kW to check which selected circuits can run together. Confirm inverter AC output, battery current limits and motor/compressor starting requirements for the final system.

- TR Pro lists charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. HP Ultra’s temperature range needs selected-configuration confirmation. A temperature range is not a full-output derating curve.

- Choose the exact housing with the installation space. TR Pro/HP Ultra list IP66, EU IP21 and TB rack IP20; TR standard and HP K list IP20 with IP54 optional. Shelter, water exposure, condensation and coastal corrosion still need project-specific assessment.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

The panel illustrates one wheeled representative housing rather than proving every Pro SKU has the same lower body or port placement. Roller is a wheel. Main Circuit Breaker and Battery Switch are separate source labels. Full embedded switch-photo content beyond the printed crop is not promoted to new interface claims.

[![Connection-side terminal labels](https://pk.elvorka.com/assets/product-details/tr-pro-terminal-labels.png)](https://pk.elvorka.com/assets/product-details/tr-pro-terminal-labels.png)

Connection-side terminal labels  Battery terminals, switch, Wi-Fi antenna and communication ports on the cabinet side.

[![Main breaker and folding handle](https://pk.elvorka.com/assets/product-details/tr-pro-breaker-side-labels.png)](https://pk.elvorka.com/assets/product-details/tr-pro-breaker-side-labels.png)

Main breaker and folding handle  Main circuit breaker and folding handle on the illustrated cabinet side.

[![Original connection-side three-quarter view](https://pk.elvorka.com/assets/product-details/tr-pro-connection-side.png)](https://pk.elvorka.com/assets/product-details/tr-pro-connection-side.png)

Original connection-side three-quarter view  Connection-side view of the cabinet, battery terminals and folding handle.

[![Original narrow side profile](https://pk.elvorka.com/assets/product-details/tr-pro-slim-side-profile.png)](https://pk.elvorka.com/assets/product-details/tr-pro-slim-side-profile.png)

Original narrow side profile  Narrow side profile of the illustrated cabinet.

[![Original circuit-switch photograph](https://pk.elvorka.com/assets/product-details/tr-pro-switch-original-photo.png)](https://pk.elvorka.com/assets/product-details/tr-pro-switch-original-photo.png)

Original circuit-switch photograph  Circuit-control switch with ON and OFF position markings.

### Know your interfaces.

#### Power connections

Positive battery terminal  Positive DC battery terminal identified on the connection side.

Negative battery terminal  Negative DC battery terminal identified on the connection side.

#### Communication

RS485  RS485 interface named in the source; pinout and compatible device list are not provided.

Wi-Fi antenna  Wi-Fi antenna identified by the original arrow.

CAN  CAN communication interface named in the source; protocol version and pinout are not specified.

RS232  RS232 communication interface named in the source; pinout is not specified.

COM1  Port named COM1; this page does not explicitly define its role or wiring.

COM0  Port named COM0; this page does not explicitly define its role or wiring.

#### Controls & indicators

Breathing light  Front status-light strip identified as a breathing light. Colour meanings and operating logic are not specified.

Main circuit breaker  Main circuit breaker identified by the original arrow. Trip ratings and wiring are not provided here.

Battery switch  Battery switch separately named in the connection-side callout; do not merge this label with Main Circuit Breaker without a model-specific manual.

#### Structure & mounting

Wall-mounted bracket  Mechanical wall-mounting bracket; not an electrical interface.

Rollers  Wheels shown on the representative housing. The label is mechanical and is not a connector or bottom communication port.

Folding handle  Mechanical folding handle; not an electrical connector.

Source: Residential ESS brochure · PDF page 4 · printed pages 7-8

---