# HP Ultra.

![HP Ultra](https://pk.elvorka.com/assets/optimized/aad85a50fc62c866-1254-q92.webp)

High-voltage battery

# HP Ultra.

A modular aluminium-alloy LFP battery stack. Six specified configurations from 8 to 48 kWh, for integration with a compatible external inverter.

INVERTER  Compatible external inverter required

ENCLOSURE  IP66 / aluminium alloy

NOMINAL ENERGY  8–48 kWh

BATTERY VOLTAGE  Confirm selected configuration

[Start your project ↗](https://pk.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | Max. DC (kW) |
| --- | --- | --- |
| HP Ultra-8.0 | 8 | 4 |
| HP Ultra-16.0 | 16 | 8 |
| HP Ultra-24.0 | 24 | 12 |
| HP Ultra-32.0 | 32 | 16 |
| HP Ultra-40.0 | 40 | 20 |
| HP Ultra-48.0 | 48 | 24 |

System voltage and inverter compatibility must be confirmed for the chosen capacity. Floor-standing or wall-mounted installation is listed. Module additions require system review.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| HP Ultra-8.0 | 950 × 315 × 575 / W × D × H | 75 |
| HP Ultra-16.0 | 950 × 315 × 880 / W × D × H | 130 |
| HP Ultra-24.0 | 950 × 315 × 1185 / W × D × H | 185 |
| HP Ultra-32.0 | 950 × 315 × 1490 / W × D × H | 240 |
| HP Ultra-40.0 | 950 × 315 × 1795 / W × D × H | 295 |
| HP Ultra-48.0 | 950 × 315 × 2100 / W × D × H | 350 |

Communication: CAN / RS485 / Wi-Fi / Bluetooth
Temperature: Confirm selected configuration

## From a city utility room to a cooler service space, plan for your home.

Pakistan’s plains, coast and northern uplands have different climate conditions. Keep selected household essentials in the plan, then match the battery format and protected equipment space to the room’s actual heat, moisture exposure and winter temperature.

Temperature:  Confirm selected configuration

ENCLOSURE  IP66 / aluminium alloy

01

### Urban lowland home: fans, refrigeration and connectivity

A dry utility room gives a household energy reserve a dedicated place near the selected circuits it supports. In warmer lowland locations, the room’s airflow and heat belong alongside the appliance list in the plan.

EU combines battery and inverter for a new indoor IP21 installation. Where a suitable inverter already exists, TR Pro offers compact 51.2 V storage; select energy capacity around the desired hours and preserve cooling and service access.

Which lights, fans, refrigeration and network devices should be supported?

- What is the highest expected temperature inside the equipment room?

02

### Coastal home: protected storage and accessible connections

A sheltered service room can organise storage for a coastal household’s selected essential circuits. Describe actual coastal air, water and condensation exposure so the equipment location becomes part of the design.

Compare a compact TR Pro battery with modular HP Ultra storage, both listed with IP66 enclosures. Choose the electrical architecture for the compatible inverter and the housing for the proposed protected position.

Can coastal air, rain, wash water or condensation reach the proposed location?

- Is the existing inverter a 51.2 V or high-voltage battery system?

03

### Cooler equipment space: a reserve with a seasonal plan

Northern uplands are cooler than the lowlands, and an unheated equipment room needs its own minimum-temperature assessment. A dedicated dry space keeps the installation accessible while the charging plan follows the actual room.

Choose integrated storage for a new complete system or battery-only storage for a compatible inverter. Several supplied families list charging from 0 °C; discuss any explicitly supported TR heating option for the exact configuration when a colder room is involved.

What are the lowest and highest expected room temperatures?

- What charging protection and confirmed heating options apply to the selected model?

Specifications

- Use kWh to plan energy for the desired duration and kW to check which selected circuits can run together. Confirm inverter AC output, battery current limits and motor/compressor starting requirements for the final system.

- TR Pro lists charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. HP Ultra’s temperature range needs selected-configuration confirmation. A temperature range is not a full-output derating curve.

- Choose the exact housing with the installation space. TR Pro/HP Ultra list IP66, EU IP21 and TB rack IP20; TR standard and HP K list IP20 with IP54 optional. Shelter, water exposure, condensation and coastal corrosion still need project-specific assessment.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

Six specified 8-48kWh configurations only. Original introduction figures show an unlabeled representative stack; no underside, complete installed rear, wiring pinout or activation interface is supplied. DC poles/breaker/heatsinks and communication/parallel/GND belong to different illustrated faces. Small native drawings must not be presented as high-resolution product photography. The broader '8.0-128.0' heading is not a list of additional individually specified models.

[![DC electrical / heatsink face - original callouts](https://pk.elvorka.com/assets/product-details/hp-ultra-dc-face-callouts.png)](https://pk.elvorka.com/assets/product-details/hp-ultra-dc-face-callouts.png)

DC electrical / heatsink face - original callouts  DC-side view showing the switch, battery terminals, DC breaker and heat-dissipation plate.

[![Communication and parallel-interface face - original callouts](https://pk.elvorka.com/assets/product-details/hp-ultra-com-face-callouts.png)](https://pk.elvorka.com/assets/product-details/hp-ultra-com-face-callouts.png)

Communication and parallel-interface face - original callouts  Communication-side labels for inverter links, backup communication, BMS debugging, parallel COM1/COM2 and GND.

[![Communication-side detail (partial oblique view)](https://pk.elvorka.com/assets/product-details/hp-ultra-communication-side-detail.png)](https://pk.elvorka.com/assets/product-details/hp-ultra-communication-side-detail.png)

Communication-side detail (partial oblique view)  Oblique detail of the stack's communication-side connector area.

[![Module top / mating surfaces](https://pk.elvorka.com/assets/product-details/hp-ultra-module-top-connectors.png)](https://pk.elvorka.com/assets/product-details/hp-ultra-module-top-connectors.png)

Module top / mating surfaces  Battery module top and mating surfaces.

### Know your interfaces.

#### Power connections

Positive Pole  Positive terminal identified by the original leader line on the electrical face.

Negative Pole  Negative terminal identified by the original leader line on the electrical face.

#### Communication

Bluetooth/WIFI Antenna  Antenna label on the upper communication-side area.

Backup Com  The brochure labels this connection 'Backup Com' but does not explain its exact role.

INV CAN/RS485 Com  The INV-labelled CAN/RS485 communication connection shown in the original diagram.

Parallel COM1  First parallel-communication label near the lower part of the illustrated interface face.

Parallel COM2  Second parallel-communication label near the lower part of the illustrated interface face.

#### Controls & indicators

Switch  Switch labelled on the DC electrical-side illustration; its detailed switching function is not specified.

DC Breaker  DC breaker on the electrical / heatsink face.

Breathing Light  Light strip called out at the upper front portion in the oblique construction view.

#### Structure & mounting

Heat Dissipation Aluminum Plate  Heat-dissipation aluminum plate called out on the slim electrical-side illustration.

Wall Mounted Bracket  Mounting brackets shown on the vent-side illustration.

PDU  PDU labels the top unit in the component hierarchy; the brochure does not expand the abbreviation.

Module  Repeated battery sections below the top PDU.

Base  Base at the bottom of the illustrated stack.

BMS Debugging Interface  BMS debugging interface identified on the communication-side illustration.

Pressure Relief Valve  Pressure-relief component called out in the communication-side oblique view.

GND  Ground connection labelled GND at the bottom of the interface-side illustration.

Source: Residential ESS brochure · PDF page 5 · printed pages 9-10

---

https://pk.elvorka.com/en/products/hp-ultra/